-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA512 ##################################################### ## N C S C ~ B E V E I L I G I N G S A D V I E S ## ##################################################### Titel : Kwetsbaarheden verholpen in DrayTek VigorSwitch Advisory ID : NCSC-2026-0328 Versie : 1.00 Kans : medium CVE ID : CVE-2026-71915, CVE-2026-71916, CVE-2026-71917, CVE-2026-71918, CVE-2026-71919, CVE-2026-71920, CVE-2026-71921, CVE-2026-71922, CVE-2026-71923, CVE-2026-71924, CVE-2026-71925, CVE-2026-71926, CVE-2026-71927, CVE-2026-71928, CVE-2026-71929, CVE-2026-71930, CVE-2026-71931, CVE-2026-71932, CVE-2026-71933, CVE-2026-71934, CVE-2026-71935, CVE-2026-71936, CVE-2026-71937, CVE-2026-71938, CVE-2026-71939, CVE-2026-71940, CVE-2026-71941, CVE-2026-71942, CVE-2026-71943 (Details over de kwetsbaarheden kunt u vinden op de Mitre website: https://cve.mitre.org/cve/) Schade : high Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') NULL Pointer Dereference Missing Authorization Uitgiftedatum : 20260826 Toepassing : DrayTek Corporation VigorSwitch FX2120 DrayTek Corporation VigorSwitch G1280 DrayTek Corporation VigorSwitch G1282 DrayTek Corporation VigorSwitch G2100 DrayTek Corporation VigorSwitch G2121 DrayTek Corporation VigorSwitch G2280x DrayTek Corporation VigorSwitch G2282x DrayTek Corporation VigorSwitch G2540x DrayTek Corporation VigorSwitch G2540xs DrayTek Corporation VigorSwitch G2542x DrayTek Corporation VigorSwitch P1280 DrayTek Corporation VigorSwitch P1281x DrayTek Corporation VigorSwitch P1282 DrayTek Corporation VigorSwitch P2100 DrayTek Corporation VigorSwitch P2121 DrayTek Corporation VigorSwitch P2280x DrayTek Corporation VigorSwitch P2282x DrayTek Corporation VigorSwitch P2540x DrayTek Corporation VigorSwitch P2540xs DrayTek Corporation VigorSwitch P2542x DrayTek Corporation VigorSwitch P2542xh DrayTek Corporation VigorSwitch PQ2121x DrayTek Corporation VigorSwitch PQ2200xb DrayTek Corporation VigorSwitch PQ2300xb DrayTek Corporation VigorSwitch PX2060 DrayTek Corporation VigorSwitch Q2121x DrayTek Corporation VigorSwitch Q2200x DrayTek Corporation VigorSwitch Q2300x DrayTek Vigor Versie(s) : Platform(s) : Beschrijving DrayTek heeft meerdere kwetsbaarheden verholpen in de VigorSwitch productlijn. De kwetsbaarheden betreffen voornamelijk command injection, buffer overflow, null pointer dereference, directory traversal en onvoldoende autorisatiecontroles in diverse functies van de DrayTek VigorSwitch apparaten. Command injection kwetsbaarheden bevinden zich onder andere in functies zoals jsonstatus, commandTable, pingtrace, webBackupAction, sysreboot, auth_set, getVid, getDetail, setDevice, rebDevice, fdftDevice, setDevProto, setTime, tftp_upgrade en setDevNet. Deze maken het mogelijk voor een aanvaller om willekeurige commando's met root privileges uit te voeren. Sommige command injection kwetsbaarheden zijn pre-authenticatie, zoals in de setget.cgi interface, waardoor geen voorafgaande authenticatie vereist is voor exploitatie. Buffer overflow kwetsbaarheden zijn aanwezig in functies zoals pingtrace, webBackupAction, sysreboot, poe_schedule_profile, switch_lan_gvrp, acl_general_setup Add ACE en Edit ACE, diag_logmail en mail_mailalert. Deze kunnen leiden tot denial of service of uitvoering van willekeurige code onder administratieve rechten. Null pointer dereference kwetsbaarheden in formlogout en setget.cgi kunnen leiden tot een denial of service door het crashen van de service. Directory traversal in getSyslogFile maakt het mogelijk om, mits geauthenticeerd, toegang te krijgen tot willekeurige bestanden op het systeem. Onvoldoende autorisatiecontroles in syslog functies stellen een aanvaller in staat om configuraties te wijzigen, services te herstarten, configuraties op te slaan of logs te wissen zonder de juiste rechten. Exploitatie van deze kwetsbaarheden vereist in de meeste gevallen geldige administratieve credentials, behalve bij de pre-authenticatie command injection en null pointer dereference in setget.cgi. Mogelijke oplossingen DrayTek heeft updates uitgebracht om de kwetsbaarheden in de VigorSwitch productlijn te verhelpen. Zie bijgevoegde referenties voor meer informatie. Referenties: Reference https://www.draytek.com/about/security-advisory/multiple- vulnerabilities-in-vigorswitch-series-august-2026 Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-buffer-overflow-via-acl-general-setup-add-ace Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-buffer-overflow-via-acl-general-setup-edit-ace Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-buffer-overflow-via-diag-logmail Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-buffer-overflow-via-mail-mailalert Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-buffer-overflow-via-pingtrace Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-buffer-overflow-via-poe-schedule-profile Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-buffer-overflow-via-switch-lan-gvrp Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-buffer-overflow-via-sysreboot Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-buffer-overflow-via-webbackupaction Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-missing-authorization-in-syslog-functions Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-null-pointer-dereference-via-formlogout Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-os-command-injection-via-auth-set Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-os-command-injection-via-commandtable Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-os-command-injection-via-fdftdevice Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-os-command-injection-via-getdetail Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-os-command-injection-via-getvid Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-os-command-injection-via-jsonstatus Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-os-command-injection-via-pingtrace Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-os-command-injection-via-rebdevice Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-os-command-injection-via-setdevice Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-os-command-injection-via-setdevnet Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-os-command-injection-via-setdevproto Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-os-command-injection-via-settime Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-os-command-injection-via-sysreboot Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-os-command-injection-via-tftp-upgrade Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-os-command-injection-via-webbackupaction Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-path-traversal-via-getsyslogfile Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-pre-authentication-null-pointer-dereference-via-setget-cgi Reference https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple- models-pre-authentication-os-command-injection-via-setget-cgi Vrijwaringsverklaring Door gebruik van deze security advisory gaat u akkoord met de navolgende voorwaarden. Ondanks dat het NCSC de grootst mogelijke zorg heeft betracht bij de samenstelling van dit beveiligingsadvies, kan het NCSC niet instaan voor de volledigheid, juistheid of (voortdurende) actualiteit van dit beveiligingsadvies. De informatie in dit beveiligingsadvies is uitsluitend bedoeld als algemene informatie voor professionele partijen. Aan de informatie in dit beveiligingsadvies kunnen geen rechten worden ontleend. Het NCSC en de Staat zijn niet aansprakelijk voor enige schade ten gevolge van het gebruik of de onmogelijkheid van het gebruik van dit beveiligingsadvies, waaronder begrepen schade ten gevolge van de onjuistheid of onvolledigheid van de informatie in dit beveiligingsadvies. Op dit beveiligingsadvies is Nederlands recht van toepassing. Alle geschillen in verband met en/of voortvloeiend uit dit beveiligingsadvies zullen worden voorgelegd aan de exclusief bevoegde rechter te Den Haag. Deze rechtskeuze geldt tevens voor de voorzieningenrechter in kort geding. -----BEGIN PGP SIGNATURE----- iQGzBAEBCgAdFiEEGSwziqblmmRNtImqgupWoL0ZhGEFAmqOrBkACgkQgupWoL0Z hGE90Qv/QiqNx/fxEE7NXfXleCFXdFwUYgjdW2ZWrXFBY2OWEyq1zWzYMOgw05S3 IidHB1X+Mdib0ObnlJeGLqWVMskY2ac47B1Asoi/5GCmoSb4s4C1Mlg3AtX+A0Ra 8bxObtPuEkk918nJnAvO9T0DqoG2BOCf7KKCw5vgv3PARCxFnjClOuD6xMb8wRkS 2FciM0g2P73KUwkgdU8Z4MbEWZUH9sSE+B/b4c5Crdu9r7+msWkOxKlkwfL2mmgf wqOupvF05mmL7HnvlYbMHscFY9WaED1cf433GdaSdFPGohyF66TSYXwEPbAChgje 3bC6/40AQuzD6NuU18Eklmo1EaTC+E3H7o9jDt9Ee/rcWnaonIkTLRoZsHIUoSA8 9//GUS34BsFRyCmZV29k8Qz6ayWF7uf22Nk1Jn4yXZMcwhfbVRx6R0MlumYem+YQ bChZJ1jKc/dIzWY+hvcHHuTz3YgcviZT8JLP0MeTn5r2sIpzLLBbQvonMIMinPvy V/EpHZCQ =2Tlq -----END PGP SIGNATURE-----